GUO Feng. Analysis on the EMG-based Digital Flexors Muscle Force Estimates[J]. China Sport Science, 2012, 32(12): 35-41. DOI: 10.16469/j.css.2012.12.002
    Citation: GUO Feng. Analysis on the EMG-based Digital Flexors Muscle Force Estimates[J]. China Sport Science, 2012, 32(12): 35-41. DOI: 10.16469/j.css.2012.12.002

    Analysis on the EMG-based Digital Flexors Muscle Force Estimates

    • Objective:To observe the effects of different filters on estimating accurate the force of digitorium flexors.Methods:18 healthy subjects were involved in the study when the digitorium flexors performed all kinds of contractions which generated the force expressed as the percent of maximal voluntary contraction(%MVC).After sampling the force and sEMG,the sEMG of digitorium flexors were processed by different methods including increasing high pass cutoff frequencies(20~480 Hz in steps of 20 Hz,24 in total) with first and sixth order filters,as well as low pass filtering with cutoff frequencies(1.0~4.0 Hz in steps of 0.1 Hz,31 in total) to produce a linear envelop.Results:The data indicated it was effective to remove 90%~95% of raw sEMG signal power to improve substantially the based-EMG force of digitorium flexors.Conclusion:It seems that a smaller high band of frequencies may be related with the force of digitorium flexors estimates,and in the present study,from a view of the digitorium flexors,the method supports the previous authors.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return